2026-11-18
Covers Y25 to Y160, a total of 10 shell diameters. Select installation direction, shell and connector material, accuracy, scale and thread at the back, the system automatically assembles the model code according to naming rules, and simultaneously outputs the pressure unit conversion result.
Convert according to international unit standards and common engineering definitions (1 psi = 6894.757 Pa, 1 kgf/cm² = 98066.5 Pa, 1 mmHg = 133.3224 Pa, 1 inH₂O = 249.0889 Pa).
Gauge PressureTaking atmospheric pressure as zero, all pressure gauge readings are gauge pressure;Absolute PressureTaking absolute vacuum as zero, absolute pressure ≈ gauge pressure + 101.325 kPa.
Dual Scale: Inner circle bar, outer circle psi is a common practice, the "Scale" on this page also provides MPa / psi conversion, which can be directly referenced for reports and drawings.
kgf/cm²About 2% difference with bar, these are two different units, not different ways of writing the same scale.
Values are all calculated from source values, no human rounding is done; engineering quotes and scale markings usually take 3-4 significant digits.
| Unit | Pa | kPa | MPa | bar | psi | kgf/cm² |
|---|
Bold "1" indicates the unit of this row. Water column units are converted according to 4°C pure water density, and mercury columns are converted according to 0°C mercury density, consistent with industry common practices.
| Scale (bar) | MPa | psi | kgf/cm² | kPa | Applicable Specification |
|---|
"Applicable Specification" automatically matches each specification scale series in the table; Y25 and Y30 have significantly smaller scale systems than medium and large specifications, and small specifications do not produce high-pressure scales. This table is for accurate conversion values, and dial markings follow the rounding rules in Section 04.
Letters are assembled in order, numbers are shell diameters, separated by "-" in between.
Dry type and oil-filled shockproof are mutually exclusive.When selecting dry type, oil-filled or silicone oil cannot be selected; when selecting shockproof oil, dry type cannot be selected back.
Iron shell and oil-filled shockproof are mutually exclusive.Iron shell (coated iron shell) can only be dry type; filled shockproof requires stainless steel shell.
Exclusivity comes from parameter table notes:
"When selecting dry type, iron shell cannot be selected; when selecting shockproof oil, dry type or iron shell cannot be selected."
General engineering method: Static pressure scale is 1/3 to 3/4, dynamic or impact pressure is reduced by one level.After filling in "Actual Working Pressure", this page will provide real-time scale utilization ratio and recommendations; less than 30% indicates the scale is too large, and reading accuracy is wasted; greater than 75% poses a risk of overpressure.Recommended range 30% – 75%
Dial Value Rounding
When "Custom Scale / Nameplate" or "Custom LOGO" is selected as "Yes", the additional requirements must be filled in with at least 10 characters, otherwise the selection form cannot be duplicated.
Anhui Xingyi Instrument Co., Ltd.
Data Source: