Pressure Gauge Selection System
Pressure Gauge Configurator

Select by parameter,
Real-time generation of model codes and specifications

Covers Y25 to Y160, a total of 10 case diameters. Select installation direction, case and connector material, accuracy, scale and thread. The system automatically assembles the model code according to naming rules, and outputs the pressure unit conversion result synchronously.

10 specifications 15 parameter dimensions 3 selectable units 11 pressure unit conversions
01

Parameter selection

Options follow the specification and move, incompatible parameters will be grayed out and the reason will be marked
ACase diameter / SpecificationDetermine the available parameter range
BConnection directionRadial / Axial / With edge
CType and shockproofDry type and oil-filled shockproof
Shockproof oil
DCase and connector materialCopper / Iron / Stainless steel
Case material
Connector material
EAccuracy levelThe smaller the value, the higher the accuracy
FScale and unitThe scale in the table is marked in bar
Dial unit
Actual working pressure (fill in according to dial unit)
Not filled
GConnector threadFollows the specification
HCustom requirementsFull specification support
Custom scale / brand
Custom LOGO
Additional requirements (self-input)0 / 10
Configured model number
—
—
bar —
    02

    Pressure unit conversion

    Pressure gauge conversion, 1 bar = 100 kPa = 14.5038 psi
    Input value
    Source unit
    Common presets

    Convert according to international unit standards and common engineering definitions (1 psi = 6894.757 Pa, 1 kgf/cm² = 98066.5 Pa, 1 mmHg = 133.3224 Pa, 1 inH₂O = 249.0889 Pa).

    Three easily confused diameters

    Gauge pressureTaking atmospheric pressure as zero, all pressure gauge readings are gauge pressure;Absolute pressureTaking absolute vacuum as zero, absolute pressure ≈ gauge pressure + 101.325 kPa.

    Dual scale: Inner circle bar, outer circle psi is a common practice. The "Scale" on this page also provides MPa / psi conversions, which can be directly referenced for reports and drawings.

    kgf/cm²Is about 2% different from bar, and is a method of writing two different units, not a difference in the same scale.

    Values are all converted from source values, no human rounding is done; engineering quotes and scale markings usually take 3-4 significant digits.

    Unit conversion table1 unit = the following value
    Unit Pa kPa MPa bar psi kgf/cm²

    Bold "1" indicates that the unit in this row is itself. Column units are converted based on the density of pure water at 4°C, and mercury columns are converted based on the density of mercury at 0°C, consistent with industry common practices.

    03

    Factory common scale cross-unit conversion

    Automatically converted from the scale serial number in the selection parameter table
    Scale (bar) MPa psi kgf/cm² kPa Applicable specifications

    "Applicable specifications" automatically matches each specification scale serial number in the table; the scale system of Y25 and Y30 is significantly smaller than medium and large specifications, and small specifications do not produce high-pressure scales. This table is for accurate conversion values, and the dial scale marking follows the rounding rules in section 04.

    04

    Model naming and selection rules

    Automatically executed based on the notes in the parameter table

    Naming rules

    Letters are assembled in order, numbers are case diameters, separated by "-" in between.

    YPressure gauge (fixed first position)
    NShockproof (oil-filled shockproof)
    BStainless steel (case)
    FAll steel (connector stainless steel)
    ZAxial direction
    TWith edge
    Example:YNBFZT-100→ Axial direction with edge, stainless steel case, all steel, oil-filled shockproof pressure gauge with a diameter of 100 mm

    Mutual restriction

    Dry type and oil-filled shockproof are mutually exclusive.When selecting dry type, oil or silicone oil cannot be selected; when selecting shockproof oil, dry type cannot be selected back.

    Iron case and oil-filled shockproof are mutually exclusive.Iron case (plated iron case) can only be dry type; oil-filled shockproof requires a stainless steel case.

    Restrictions come from parameter table notes:
    "When selecting dry type and iron case, shockproof oil cannot be selected. When selecting shockproof oil, dry type or iron case cannot be selected."

    Scale verification

    General engineering method: Static pressure scale is 1/3 to 3/4, dynamic or impact pressure is reduced by one level.After filling in "Actual working pressure", this page will give the scale utilization rate and suggestions in real time. Less than 30% indicates that the scale is too large, wasting reading accuracy; more than 75% poses an overpressure risk.Recommended range 30% – 75%

    Dial value rounding

    When selecting bar, keep the value in the table; when selecting MPa, take 1/10 of the original value; when selecting psi, take 14.5 times the original value and round it, keeping at most three significant digits, and padding with zeros afterwards.

    Example: 15 bar → 1.5 MPa → 218 psi (15 × 14.5 = 217.5, rounded to three significant digits is 218).

    When "Custom scale / brand" or "Custom LOGO" is selected as "Yes", the additional requirements must be filled in with at least 10 characters, otherwise the selection template cannot be duplicated.

    Anhui Xingyi Instrument Co., Ltd.

    Data source:

    (Sheet1, 10 models × 15 parameter columns, including 3 rows of notes).Diameter description: Duplicate items in the original table "Scale (bar)" column (e.g., 50 appearing twice) have been removed; the original scale unit cells for Y25 were numerical values 50100150200300400. This page is restored to 50 / 100 / 150 / 200 / 300 / 400. Please verify with the actual product directory.This page is a selection auxiliary tool. The final specifications, material part numbers, and prices should be confirmed with the official quotation sheet and drawings; the page is a single file offline version, and the data has been embedded in the code and does not require network access.