Anhui Xingyi Instrument Co., Ltd. Pressure Gauge Selection System
Pressure Gauge Configurator

Select by parameter,
Real-time generation of model codes and specifications

Covers Y25 to Y160, a total of 10 case diameters. Select installation direction, case and connection material, accuracy, scale and thread pitch. The system automatically assembles the model code according to the naming rules, and simultaneously outputs the pressure unit conversion result.

10 specifications 15 parameter dimensions 3 selectable units 11 pressure unit conversions
01

Parameter selection

Options move with the specification, and inconsistent parameters will be grayed out and the reason will be marked.
ACase diameter / SpecificationDetermine the available parameter range
BConnection directionRadial / Axial / With edge
CType and shockproofDry type and oil-filled are mutually exclusive
Shockproof oil
DCase and connection materialCopper / Iron / Stainless steel
Case material
Connection material
EAccuracy levelThe smaller the value, the more accurate
FScale and unitThe scale in the table is marked in bar
Dial unit
Actual working pressure (filled in according to dial unit)
Not filled
GConnection threadChanges with specification
HCustom requirementsFull specification support
Custom scale / nameplate
Custom LOGO
Additional requirements (self-input)0 / 10
Configured model number
—
—
bar —
    02

    Pressure unit conversion

    Pressure conversion, 1 bar = 100 kPa = 14.5038 psi
    Input value
    Source unit
    Common presets

    Convert according to international unit standards and common engineering definitions (1 psi = 6894.757 Pa, 1 kgf/cm² = 98066.5 Pa, 1 mmHg = 133.3224 Pa, 1 inH₂O = 249.0889 Pa).

    Three easily confused diameters

    Gauge pressureTaking atmospheric pressure as zero, all pressure gauge readings are gauge pressure;Absolute pressureTaking absolute vacuum as zero, absolute pressure ≈ gauge pressure + 101.325 kPa.

    Dual scale: Inner scale bar, outer scale psi is a common practice. This page's 'Scale' also provides MPa / psi conversions, which can be directly referenced for quotation and drawings.

    kgf/cm²differs from bar by about 2%, these are two different units, not different ways of writing the same scale.

    Values are all converted from source values, and no human rounding is done; engineering quotes and scale markings usually take 3-4 significant digits.

    Unit conversion table1 unit = the following value
    Unit Pa kPa MPa bar psi kgf/cm²

    Bold '1' indicates the unit of this row. Column units are converted based on 4 °C pure water density, and mercury columns are converted based on 0 °C mercury density, consistent with industry common practices.

    03

    Factory common scale cross-unit comparison

    Taken from the scale sequence in the model parameter table, automatically converted
    Scale (bar) MPa psi kgf/cm² kPa Applicable specifications

    'Applicable specifications' automatically matches each specification scale sequence in the table; Y25 and Y30 have significantly smaller scale systems than medium and large specifications, and small specifications do not produce high-pressure scales. This table is for accurate conversion values, and the dial scale marking follows the rounding rules in Section 04.

    04

    Model naming and selection rules

    Automatically executed based on the notes in the parameter table

    Naming rules

    Letters are assembled in order, numbers are case diameters, separated by '-' in between.

    YPressure gauge (fixed first position)
    NShockproof (oil-filled shockproof)
    BStainless steel (case)
    FAll steel (stainless steel connection)
    ZAxial direction
    TWith edge
    Example:YNBFZT-100→ Case diameter 100 mm, axial direction with edge, stainless steel case, all steel, oil-filled shockproof pressure gauge

    Mutual exclusion

    Dry type and oil-filled are mutually exclusive.When selecting dry type, oil-filled or silicone oil cannot be selected; after selecting shockproof oil, dry type cannot be selected.

    Iron case and oil-filled are mutually exclusive.Iron case (coated iron case) can only be dry type; oil-filled shockproof requires a stainless steel case.

    Exclusions come from parameter table notes:
    'Select dry type, iron case cannot select shockproof oil; after selecting shockproof oil, dry type or iron case cannot be selected.'

    Scale verification

    General engineering method: Static pressure is the scale of 1/3 ~ 3/4, pulse or impact pressure is reduced by one level.

    After filling in 'Actual working pressure', this page will provide real-time scale utilization ratio and recommendations; less than 30% indicates the scale is too large, wasting reading accuracy; greater than 75% poses an overpressure risk.

    Recommended range 30% – 75%

    Dial value rounding

    When selecting bar, keep the value in the table; when selecting MPa, take 1/10 of the original value; when selecting psi, take 14.5 times the original value and round it, keeping at most three significant digits, and append zeros at the end.

    Example: 15 bar → 1.5 MPa → 218 psi (15 × 14.5 = 217.5, rounded to three significant digits is 218).

    When 'Custom scale / nameplate' or 'Custom LOGO' is selected as 'Yes', the additional requirements must be filled in with at least 10 characters, otherwise the selection form cannot be duplicated.

    Anhui Xingyi Instrument Co., Ltd.

    Data source:(Sheet1, 10 models × 15 parameter columns, including 3 rows of notes).

    Diameter description: Duplicate items in the original table's 'Scale (bar)' column (e.g., 50 appearing twice) have been removed; the scale units for Y25 were originally numerical values 50100150200300400. This page restores them to 50 / 100 / 150 / 200 / 300 / 400. Please verify with the actual product directory.

    This page is a model selection auxiliary tool. The final specifications, material part numbers, and prices should be confirmed with the official quotation and drawings; the page is a single document offline version, and the data has been embedded in the code and cannot be called online.