2026-11-18
Covers Y25 to Y160, a total of 10 case diameters. Select installation direction, case and connector material, accuracy, scale and thread. The system automatically assembles the model code according to naming rules and outputs the pressure unit conversion result.
Convert according to international unit standards and common engineering definitions (1 psi = 6894.757 Pa, 1 kgf/cm² = 98066.5 Pa, 1 mmHg = 133.3224 Pa, 1 inH₂O = 249.0889 Pa).
Gauge PressureTaking atmospheric pressure as zero point, all pressure gauge readings are gauge pressure;Absolute PressureTaking absolute vacuum as zero point, absolute pressure ≈ gauge pressure + 101.325 kPa.
Dual Scale: Inner circle bar, outer circle psi is a common practice; This page 'Scale' also provides conversions for MPa / psi, which can be directly compared with reports and drawings.
kgf/cm²Approximately 2% difference with bar, these are two different units, not different ways of writing the same scale.
Values are all calculated from source values, no human rounding is done; Engineering quotes and scale markings usually take 3-4 significant digits.
| Unit | Pa | kPa | MPa | bar | psi | kgf/cm² |
|---|
The bold '1' indicates that the unit in this row is itself. Water column units are converted according to 4 °C pure water density, mercury column is converted according to 0 °C mercury density, consistent with industry common practice.
| Scale (bar) | MPa | psi | kgf/cm² | kPa | Applicable Specifications |
|---|
'Applicable Specifications' automatically matches each specification scale in the table; The scale system of Y25 and Y30 is obviously smaller than medium and large specifications, and small specifications do not produce high-pressure scales. This table is for accurate conversion values, and the dial scale markings follow the integer rules in Section 04.
Letters are assembled in order, numbers are case diameters, separated by '-' in between.
Dry type and oil-filled mutual restraint.When selecting dry type, oil-filled or silicone oil cannot be selected; After selecting shockproof oil, dry type cannot be selected.
Iron case and oil-filled mutual restraint.Iron case (coated iron case) can only be dry type; Oil-filled shockproof requires a stainless steel case.
Restraints come from parameter table annotations:
'Select dry type, iron case cannot select shockproof oil, after selecting shockproof oil, cannot select dry type or iron case'.
General engineering practice: Static pressure is 1/3 to 3/4 of the scale, dynamic or impulse pressure is reduced by one level.After filling in 'Actual Working Pressure', this page will give real-time scale utilization ratio and recommendations. Less than 30% indicates the scale is too large, wasting reading accuracy; More than 75% has the risk of overpressure.Recommended range 30% – 75%
Dial Value Rounding
When 'Custom Scale / Nameplate' or 'Custom LOGO' is selected as 'Yes', additional requirements must be filled in with at least 10 characters, otherwise the selection form cannot be copied.
Anhui Xingyi Instrument Co., Ltd.
Data Source: