Covers Y25 to Y160, a total of 10 case diameters. Select installation direction, case and connection material, accuracy, scale and thread end, system automatically assembles model code according to naming rules, and simultaneously outputs pressure unit conversion results.
Conversion according to international unit standards and common engineering definitions (1 psi = 6894.757 Pa, 1 kgf/cm² = 98066.5 Pa, 1 mmHg = 133.3224 Pa, 1 inH₂O = 249.0889 Pa).
Gauge pressureTaking atmospheric pressure as zero, all pressure gauge readings are gauge pressure;Absolute pressureTaking absolute vacuum as zero, absolute pressure ≈ gauge pressure + 101.325 kPa.
Dual scale: Inner circle bar, outer circle psi is a common practice, this page 'Scale' also outputs MPa / psi conversion, which can be directly referenced for quotation and drawings.
kgf/cm²Approximately 2% difference with bar, these are two different units, not different ways of writing the same scale.
Values are all calculated from source values, no human rounding is done; engineering quotation and scale markings usually take 3-4 significant digits.
| Unit | Pa | kPa | MPa | bar | psi | kgf/cm² |
|---|
Bold '1' indicates that the unit in this row is itself. Water column units are converted according to 4°C pure water density, and mercury columns are converted according to 0°C mercury density, consistent with industry common practices for instrument rows.
| Scale (bar) | MPa | psi | kgf/cm² | kPa | Applicable specifications |
|---|
'Applicable specifications' automatically matches each specification scale sequence in the table; the scale system of Y25 and Y30 is significantly smaller than medium and large specifications, and small specifications do not produce high-pressure scales. This table is for accurate conversion values, and the dial scale is marked according to the integer rule in section 04.
Letters are assembled in order, numbers are case diameters, separated by '-' in between.
Dry type and oil-filled shock absorption are mutually exclusive.When selecting dry type, oil-filled or silicone oil cannot be selected; after selecting shockproof oil, dry type cannot be selected.
Iron case and oil-filled shock absorption are mutually exclusive.Iron cases (coated iron cases) can only be dry type; oil-filled shock absorption requires stainless steel cases.
Exclusions come from parameter table annotations:
'Select dry type, iron cases cannot select shockproof oil; after selecting shockproof oil, dry type or iron cases cannot be selected'.
General engineering method: Static pressure is measured within 1/3 to 3/4 of the scale; dynamic or impulse pressure is reduced by one level.After filling in 'Actual working pressure', this page will display the scale utilization ratio and recommendations in real-time. Less than 30% indicates the scale is too large, wasting reading accuracy; greater than 75% poses an overpressure risk.Recommended range 30% – 75%
Dial value rounding
When 'Custom scale / brand' or 'Custom LOGO' is selected as 'Yes', additional requirements must be filled in with at least 10 characters, otherwise the selection form cannot be duplicated.