2026-11-18
Covers Y25 to Y160, a total of 10 case diameters. Select installation direction, case and connector material, accuracy, scale and thread after, the system automatically assembles the model code according to the naming rules, and simultaneously outputs the pressure unit conversion result.
Convert according to international unit standards and common engineering definitions (1 psi = 6894.757 Pa, 1 kgf/cm² = 98066.5 Pa, 1 mmHg = 133.3224 Pa, 1 inH₂O = 249.0889 Pa).
Gauge PressureAtmospheric pressure as zero point, all pressure gauge readings are gauge pressure;Absolute PressureAbsolute zero as zero point, absolute pressure ≈ gauge pressure + 101.325 kPa.
Dual Scale: Inner circle bar, outer circle psi is a common practice, the 'Scale' on this page also provides MPa / psi conversion, which can be directly compared with the quotation and drawings.
kgf/cm²differs from bar by about 2%, these are two different units, not different ways of writing the same scale.
Values are all calculated from source values, not rounded by humans; engineering quotations and scale markings usually take 3-4 significant digits.
| Unit | Pa | kPa | MPa | bar | psi | kgf/cm² |
|---|
Bold '1' indicates the unit of this row. Water column units are calculated based on 4°C pure water density, mercury columns are calculated based on 0°C mercury density, consistent with industry common practices for instrument rows.
| Scale (bar) | MPa | psi | kgf/cm² | kPa | Applicable Specification |
|---|
'Applicable Specification' automatically matches each specification scale sequence in the table; Y25 and Y30 have significantly smaller scale systems than medium and large specifications, and small specifications do not produce high-pressure scales. This table is for accurate conversion values, and dial scale markings follow the rounding rules in Section 04.
Letters are assembled in order, numbers are case diameters, separated by '-' in between.
Dry type and oil-filled are mutually exclusive.When selecting dry type, oil or silicone oil cannot be selected; after selecting shockproof oil, dry type or silicone oil cannot be selected.
Iron case and oil-filled are mutually exclusive.Iron case (plated iron case) can only be dry type; oil-filled shockproof requires a stainless steel case.
Restrictions come from parameter table notes:
'Select dry type, iron case cannot select shockproof oil; after selecting shockproof oil, dry type or iron case cannot be selected'.
General engineering method: static pressure scale is 1/3 to 3/4, dynamic or impulse pressure is reduced by one level.After filling in 'Actual Working Pressure', this page will provide real-time scale utilization ratio and recommendations. Less than 30% indicates the scale is too large, wasting reading accuracy; more than 75% poses an overpressure risk.Recommended range 30% – 75%
Dial Value Rounding
When 'Custom Scale / Brand' or 'Custom LOGO' is selected as 'Yes', additional requirements must be filled in with at least 10 characters, otherwise the model sample cannot be duplicated.
Anhui Xingyi Instrument Co., Ltd.
Data Source: