Casa >
Notícia
> Notícias da empresa sobre Modelo

Modelo

2026-11-18

Últimas notícias da empresa sobre Modelo
Pressure Gauge Model Selection System
Pressure Gauge Configurator

Select by parameter,
Real-time generation of model codes and specifications

Covers Y25 to Y160, a total of 10 case diameters. Select installation direction, case and connector material, accuracy, scale and thread after, the system automatically assembles the model code according to the naming rules, and simultaneously outputs the pressure unit conversion result.

10 specifications 15 parameter dimensions 3 selectable units 11 pressure unit conversions
01

Parameter Model

Options move with the specification, incompatible parameters will be grayed out and the reason will be marked
ACase Diameter / SpecificationDetermine usable parameter range
BConnection DirectionRadial / Axial / Flanged
CType and ShockproofDry type and oil-filled are mutually exclusive
Shockproof oil
DCase and Connector MaterialCopper / Iron / Stainless Steel
Case Material
Connector Material
EAccuracy LevelThe smaller the value, the more accurate
FScale and UnitThe scale on the table is marked in bar
Dial Unit
Actual Working Pressure (Fill in according to dial unit)
Not filled
GConnector ThreadChanges with specification
HCustom RequirementsFull specification support
Custom Scale / Brand
Custom LOGO
Additional requirements (self-input)0 / 10
Configured Model
—
—
bar —
    02

    Pressure Unit Conversion

    Table pressure conversion, 1 bar = 100 kPa = 14.5038 psi
    Input Value
    Source Unit
    Common Presets

    Convert according to international unit standards and common engineering definitions (1 psi = 6894.757 Pa, 1 kgf/cm² = 98066.5 Pa, 1 mmHg = 133.3224 Pa, 1 inH₂O = 249.0889 Pa).

    Three easily confused interfaces

    Gauge PressureAtmospheric pressure as zero point, all pressure gauge readings are gauge pressure;Absolute PressureAbsolute zero as zero point, absolute pressure ≈ gauge pressure + 101.325 kPa.

    Dual Scale: Inner circle bar, outer circle psi is a common practice, the 'Scale' on this page also provides MPa / psi conversion, which can be directly compared with the quotation and drawings.

    kgf/cm²differs from bar by about 2%, these are two different units, not different ways of writing the same scale.

    Values are all calculated from source values, not rounded by humans; engineering quotations and scale markings usually take 3-4 significant digits.

    Unit Conversion Table1 Unit = Value Below
    Unit Pa kPa MPa bar psi kgf/cm²

    Bold '1' indicates the unit of this row. Water column units are calculated based on 4°C pure water density, mercury columns are calculated based on 0°C mercury density, consistent with industry common practices for instrument rows.

    03

    Factory Common Scale Cross-Unit Conversion

    Automatically converted from scale sequence in model parameters
    Scale (bar) MPa psi kgf/cm² kPa Applicable Specification

    'Applicable Specification' automatically matches each specification scale sequence in the table; Y25 and Y30 have significantly smaller scale systems than medium and large specifications, and small specifications do not produce high-pressure scales. This table is for accurate conversion values, and dial scale markings follow the rounding rules in Section 04.

    04

    Model Naming and Selection Rules

    Automatically executed based on parameter table notes

    Naming Rules

    Letters are assembled in order, numbers are case diameters, separated by '-' in between.

    YPressure Gauge (Fixed First Position)
    NShockproof (Oil Filled)
    BStainless Steel (Case)
    FAll Steel (Connector Stainless Steel)
    ZAxial Direction
    TFlanged
    Example:YNBFZT-100→ Case diameter 100 mm, axial direction with flange, stainless steel case, all steel, oil-filled shockproof pressure gauge

    Mutual Exclusivity

    Dry type and oil-filled are mutually exclusive.When selecting dry type, oil or silicone oil cannot be selected; after selecting shockproof oil, dry type or silicone oil cannot be selected.

    Iron case and oil-filled are mutually exclusive.Iron case (plated iron case) can only be dry type; oil-filled shockproof requires a stainless steel case.

    Restrictions come from parameter table notes:
    'Select dry type, iron case cannot select shockproof oil; after selecting shockproof oil, dry type or iron case cannot be selected'.

    Scale Verification

    General engineering method: static pressure scale is 1/3 to 3/4, dynamic or impulse pressure is reduced by one level.After filling in 'Actual Working Pressure', this page will provide real-time scale utilization ratio and recommendations. Less than 30% indicates the scale is too large, wasting reading accuracy; more than 75% poses an overpressure risk.Recommended range 30% – 75%

    Dial Value Rounding

    When selecting bar, keep the value in the table; when selecting MPa, take 1/10 of the original value; when selecting psi, take 14.5 times the original value and round it, keeping at most three significant digits, and append zeros.

    Example: 15 bar → 1.5 MPa → 218 psi (15 × 14.5 = 217.5, rounded and then kept as 218 with three significant digits).

    When 'Custom Scale / Brand' or 'Custom LOGO' is selected as 'Yes', additional requirements must be filled in with at least 10 characters, otherwise the model sample cannot be duplicated.

    Anhui Xingyi Instrument Co., Ltd.

    Data Source:

    (Sheet1, 10 model codes × 15 parameter columns, including 3 rows of notes).Interface Description: Duplicate items in the original table's 'Scale (bar)' column (e.g., 50 appearing twice) have been removed; the original scale unit for the Y25 row was 50100150200300400, this page displays 50 / 100 / 150 / 200 / 300 / 400, please verify with the actual product catalog.This page is a model selection auxiliary tool. The final specifications, material part numbers, and prices should be confirmed with the official quotation and drawings; the page is a single-file offline version, and the data has been embedded in the code and cannot be accessed online.