Pressure Gauge Selection System
Pressure Gauge Configurator

Select by parameter,
Real-time generation of model codes and specifications

Covers Y25 to Y160, a total of 10 case diameters. Select installation direction, case and connector material, accuracy, scale and thread. The system automatically assembles the model code according to the naming rules and simultaneously outputs the pressure unit conversion results.

10 specifications 15 parameter dimensions 3 selectable units 11 pressure unit conversions
01

Parameter Selection

Options follow the specification and move together, inconsistent parameters will be grayed out and the reason will be marked
ACase Diameter / SpecificationDetermine the applicable parameter range
BConnection DirectionRadial / Axial / With Edge
CType and ShockproofDry type and gas-filled shockproof are mutually exclusive
Gas-filled shockproof
DCase and Connector MaterialCopper / Iron / Stainless Steel
Case Material
Connector Material
EAccuracy LevelThe smaller the value, the higher the accuracy
FScale and UnitThe scale in the table is marked in bar
Dial Unit
Actual Working Pressure (Fill in according to dial unit)
Not Filled
GConnector ThreadFollows specification changes
HCustom RequirementsFull specification support
Custom Scale / Brand
Custom LOGO
Additional Requirements (Self-input)0 / 10
Configured Model
—
—
bar —
    02

    Pressure Unit Conversion

    Table pressure conversion, 1 bar = 100 kPa = 14.5038 psi
    Input Value
    Source Unit
    Common Preset

    Convert according to international unit standards and common engineering definitions (1 psi = 6894.757 Pa, 1 kgf/cm² = 98066.5 Pa, 1 mmHg = 133.3224 Pa, 1 inH₂O = 249.0889 Pa).

    Three easily confused interfaces

    Gauge PressureTaking atmospheric pressure as zero, all pressure gauge readings are gauge pressure;Absolute PressureTaking absolute vacuum as zero, absolute pressure ≈ gauge pressure + 101.325 kPa.

    Dual Scale: Inner circle bar, outer circle psi is a common practice, the "Scale" on this page also outputs MPa / psi conversions, which can be directly compared with the quotation and drawings.

    kgf/cm²differs from bar by about 2%, these are two different units, not the same scale writing method.

    Values are all calculated from source values, no human rounding is done; engineering quotations and scale markings usually take 3-4 significant digits.

    Unit Conversion Table1 Unit = The following value
    Unit Pa kPa MPa bar psi kgf/cm²

    Bold "1" indicates that the unit in this row is itself. Water column units are converted based on 4°C pure water density, mercury column is converted based on 0°C mercury density, consistent with industry common practices.

    03

    Factory Common Scale Cross-Unit Conversion

    Taken from the scale sequence in the model parameter table, automatically converted
    Scale (bar) MPa psi kgf/cm² kPa Applicable Specification

    "Applicable Specification" automatically matches each specification scale sequence in the table; the scale system of Y25 and Y30 is significantly smaller than medium and large specifications, and small specifications do not produce high-pressure scales. This table is for accurate conversion values, and the dial scale marking follows the rounding rules in Section 04.

    04

    Model Naming and Selection Rules

    Automatically executed based on the notes in the parameter table

    Naming Rules

    Letters are assembled in order, numbers are case diameter, separated by "-" in between.

    YPressure Gauge (Fixed first position)
    NShockproof (Gas-filled shockproof)
    BStainless Steel (Case)
    FAll Steel (Connector Stainless Steel)
    ZAxial
    TWith Edge
    Example:YNBFZT-100→ Case diameter 100 mm, axial with edge, stainless steel case all steel, gas-filled shockproof pressure gauge

    Mutual Exclusivity

    Dry type and gas-filled shockproof are mutually exclusive.When selecting dry type, gas-filled oil or silicone oil cannot be selected; after selecting gas-filled shockproof, dry type or iron case cannot be selected.

    Iron case and gas-filled shockproof are mutually exclusive.Iron case (coated iron case) can only be dry type; gas-filled shockproof requires a stainless steel case.

    Restrictions come from parameter table notes:
    "Select dry type, iron case cannot select shockproof oil, after selecting shockproof oil, dry type or iron case cannot be selected".

    Scale Verification

    General engineering practice: Static pressure scale is 1/3 to 3/4, pulsating or impact pressure is reduced by one level.After filling in "Actual Working Pressure", this page will display the scale utilization rate and recommendations in real time. Less than 30% indicates that the scale is too large and the reading accuracy is wasted; more than 75% has the risk of overpressure.Recommended range 30% – 75%

    Dial Value Rounding

    When selecting bar, keep the value in the table; when selecting MPa, take 1/10 of the original value; when selecting psi, take 14.5 times the original value and round it, keeping at most three significant digits, and add zeros at the end.

    Example: 15 bar → 1.5 MPa → 218 psi (15 × 14.5 = 217.5, rounded to three significant digits is 218).

    When "Custom Scale / Brand" or "Custom LOGO" is selected as "Yes", the additional requirements must be filled in with at least 10 characters, otherwise the selection form cannot be duplicated.

    Anhui Xingyi Instrument Co., Ltd.

    Data Source:

    (Sheet1, 10 models × 15 parameter columns, including 3 rows of notes).Interface Description: Duplicate items in the original table "Scale (bar)" column (e.g., 50 appears twice) have been removed; the scale unit cells in the Y25 row were originally numerical values 50100150200300400, this page restores them to 50 / 100 / 150 / 200 / 300 / 400, please verify with the actual product directory.This page is a selection auxiliary tool, the final specification, material part number and price shall be confirmed with the official quotation and drawing; the page is a single file offline version, the data has been embedded in the code, and does not require network access.