Covers Y25 to Y160, a total of 10 case diameters. Select installation direction, case and connector material, accuracy, scale and thread. The system automatically assembles the model code according to the naming rules and simultaneously outputs the pressure unit conversion results.
Convert according to international unit standards and common engineering definitions (1 psi = 6894.757 Pa, 1 kgf/cm² = 98066.5 Pa, 1 mmHg = 133.3224 Pa, 1 inH₂O = 249.0889 Pa).
Gauge PressureTaking atmospheric pressure as zero, all pressure gauge readings are gauge pressure;Absolute PressureTaking absolute vacuum as zero, absolute pressure ≈ gauge pressure + 101.325 kPa.
Dual Scale: Inner circle bar, outer circle psi is a common practice, the "Scale" on this page also outputs MPa / psi conversions, which can be directly compared with the quotation and drawings.
kgf/cm²differs from bar by about 2%, these are two different units, not the same scale writing method.
Values are all calculated from source values, no human rounding is done; engineering quotations and scale markings usually take 3-4 significant digits.
| Unit | Pa | kPa | MPa | bar | psi | kgf/cm² |
|---|
Bold "1" indicates that the unit in this row is itself. Water column units are converted based on 4°C pure water density, mercury column is converted based on 0°C mercury density, consistent with industry common practices.
| Scale (bar) | MPa | psi | kgf/cm² | kPa | Applicable Specification |
|---|
"Applicable Specification" automatically matches each specification scale sequence in the table; the scale system of Y25 and Y30 is significantly smaller than medium and large specifications, and small specifications do not produce high-pressure scales. This table is for accurate conversion values, and the dial scale marking follows the rounding rules in Section 04.
Letters are assembled in order, numbers are case diameter, separated by "-" in between.
Dry type and gas-filled shockproof are mutually exclusive.When selecting dry type, gas-filled oil or silicone oil cannot be selected; after selecting gas-filled shockproof, dry type or iron case cannot be selected.
Iron case and gas-filled shockproof are mutually exclusive.Iron case (coated iron case) can only be dry type; gas-filled shockproof requires a stainless steel case.
Restrictions come from parameter table notes:
"Select dry type, iron case cannot select shockproof oil, after selecting shockproof oil, dry type or iron case cannot be selected".
General engineering practice: Static pressure scale is 1/3 to 3/4, pulsating or impact pressure is reduced by one level.After filling in "Actual Working Pressure", this page will display the scale utilization rate and recommendations in real time. Less than 30% indicates that the scale is too large and the reading accuracy is wasted; more than 75% has the risk of overpressure.Recommended range 30% – 75%
Dial Value Rounding
When "Custom Scale / Brand" or "Custom LOGO" is selected as "Yes", the additional requirements must be filled in with at least 10 characters, otherwise the selection form cannot be duplicated.