Anhui Xingyi Instrument Co., Ltd. Pressure Gauge Selection System
Pressure Gauge Configurator

Select by parameter,
Real-time generation of model codes and specifications

Covering Y25 to Y160, a total of 10 case diameters. Select installation direction, case and connector material, accuracy, range and thread, system automatically assembles model code according to naming rules, and outputs pressure unit conversion results simultaneously.

10 specifications 15 parameter dimensions 3 selectable units 11 pressure unit conversions
01

Parameter Selection

Options move with the specification, inconsistent parameters will be grayed out and the reason will be marked
ACase Diameter / SpecificationDetermine the available parameter range
BConnection DirectionRadial / Axial / With edge
CType and ShockproofDry type and oil-filled shockproof are mutually exclusive
Shockproof oil
DCase and Connector MaterialCopper / Iron / Stainless steel
Case Material
Connector Material
EAccuracy LevelThe smaller the value, the higher the accuracy
FRange and UnitThe range in the table is marked in bar
Dial Unit
Actual Working Pressure (Fill in according to dial unit)
Not filled
GConnector ThreadChanges with specification
HCustom RequirementsFull specification support
Custom Range / Nameplate
Custom LOGO
Additional Requirements (Self-input)0 / 10
Configured Model
—
—
bar —
    02

    Pressure Unit Conversion

    Pressure conversion, 1 bar = 100 kPa = 14.5038 psi
    Input Value
    Source Unit
    Common Presets

    Convert according to international unit standards and common engineering definitions (1 psi = 6894.757 Pa, 1 kgf/cm² = 98066.5 Pa, 1 mmHg = 133.3224 Pa, 1 inH₂O = 249.0889 Pa).

    Three easily confused interfaces

    Gauge PressureTaking atmospheric pressure as zero, all pressure gauge readings are gauge pressure;Absolute PressureTaking absolute vacuum as zero, absolute pressure ≈ gauge pressure + 101.325 kPa.

    Dual Scale: Inner scale bar, outer scale psi is a common practice, the "Range" on this page also provides MPa / psi conversion, which can be directly compared with the quotation and drawings.

    kgf/cm²differs from bar by about 2%, these are two different units, not different ways of writing the same scale.

    Values are all calculated from source values, no human rounding is done; engineering quotations and scale markings usually take 3-4 significant digits.

    Unit Conversion Table1 unit = the following value
    Unit Pa kPa MPa bar psi kgf/cm²

    The bold "1" indicates that the unit in this row is itself. Water column units are calculated based on the density of pure water at 4°C, mercury columns are calculated based on the density of mercury at 0°C, consistent with common industry practices for instrument rows.

    03

    Factory Common Range Cross-reference

    Ranges are automatically converted from the selection table parameters
    Range (bar) MPa psi kgf/cm² kPa Applicable Specification

    "Applicable Specification" automatically matches each specification range in the table; the range system of Y25 and Y30 is obviously smaller than medium and large specifications, and small specifications do not produce high-pressure ranges. This table is for accurate conversion values, and the dial scale marking follows the rounding rules in Section 04.

    04

    Model Naming and Selection Rules

    Automatically executed based on parameter table annotations

    Naming Rules

    Letters are assembled in order, numbers are case diameter, separated by "-" in the middle.

    YPressure Gauge (Fixed first position)
    NShockproof (Oil-filled shockproof)
    BStainless Steel (Case)
    FAll Steel (Connector Stainless Steel)
    ZAxial Direction
    TWith edge
    Example:YNBFZT-100→ Case diameter 100 mm, axial direction with edge, stainless steel case all steel, oil-filled shockproof pressure gauge

    Mutual Exclusivity

    Dry type and oil-filled shockproof are mutually exclusive.When selecting dry type, oil-filled or silicone oil cannot be selected; after selecting shockproof oil, dry type or iron case cannot be selected.

    Iron case and oil-filled shockproof are mutually exclusive.Iron case (plated iron case) can only be dry type; oil-filled shockproof requires a stainless steel case.

    Exclusivity comes from parameter table annotations:
    "Select dry type, iron case cannot select shockproof oil, after selecting shockproof oil, dry type or iron case cannot be selected."

    Range Verification

    General engineering method: static pressure is the range of 1/3 ~ 3/4, pulse or impact pressure is reduced by one level.

    After filling in "Actual Working Pressure", this page will display the range utilization rate and recommendations in real-time. Less than 30% indicates that the range is too large, wasting reading accuracy; more than 75% poses a risk of overpressure.

    Recommended range 30% – 75%

    Dial Value Rounding

    When selecting bar, keep the value in the table; when selecting MPa, take 1/10 of the original value; when selecting psi, take 14.5 times the original value and round it, keeping at most three significant digits, and append zeros at the end.

    Example: 15 bar → 1.5 MPa → 218 psi (15 × 14.5 = 217.5, rounded to three significant digits is 218).

    When "Custom Range / Nameplate" or "Custom LOGO" is selected as "Yes", the additional requirements must be filled in with at least 10 characters, otherwise the selection form cannot be reproduced.

    Anhui Xingyi Instrument Co., Ltd.

    Data Source:(Sheet1, 10 models × 15 parameter columns, including 3 annotation rows).

    Interface Description: Duplicate items in the original "Range (bar)" column (e.g., 50 appears twice) have been removed; the range units in the Y25 row were originally numerical values 50100150200300400, this page restores them to 50 / 100 / 150 / 200 / 300 / 400, please verify with the actual product directory.

    This page is a selection auxiliary tool, the final specification, material number and price shall be confirmed with the official quotation and drawings; the page is a single document offline version, the data has been embedded in the code, and does not require network access.