Covers Y25 to Y160, a total of 10 case diameters. Select installation direction, case and connector material, accuracy, scale and thread, system automatically assembles model code according to naming rules, and simultaneously outputs pressure unit conversion results.
Convert according to international unit standards and common engineering definitions (1 psi = 6894.757 Pa, 1 kgf/cm² = 98066.5 Pa, 1 mmHg = 133.3224 Pa, 1 inH₂O = 249.0889 Pa).
Gauge PressureTakes atmospheric pressure as zero point, all pressure gauge readings are gauge pressure;Absolute PressureTakes absolute vacuum as zero point, absolute pressure ≈ gauge pressure + 101.325 kPa.
Dual ScaleInner circle bar, outer circle psi is a common practice; This page 'Scale' also provides conversions for MPa / psi, which can be directly referenced against quotation and drawings.
kgf/cm²Is about 2% different from bar, these are two different units, not the same scale representation.
Values are all calculated from source values, no human rounding is done; Engineering quotation and scale markings usually take 3~4 significant digits.
| Unit | Pa | kPa | MPa | bar | psi | kgf/cm² |
|---|
Bold '1' indicates that the unit in this row is itself. Column units are calculated based on 4°C pure water density, mercury column is calculated based on 0°C mercury density, consistent with industry common practices.
| Scale (bar) | MPa | psi | kgf/cm² | kPa | Applicable Specifications |
|---|
'Applicable Specifications' automatically matches each specification scale series in the table; The scale system of Y25 and Y30 is significantly smaller than medium and large specifications, and small specifications do not produce high-pressure scales. This table is for accurate conversion values, and dial markings follow the rounding rules in Section 04.
Letters are assembled in order, numbers are case diameters, separated by '-' in the middle.
Dry type and gas-filled shockproof are mutually exclusive.When selecting dry type, gas-filled oil or silicone oil cannot be selected; After selecting shockproof oil, dry type cannot be selected.
Iron case and gas-filled shockproof are mutually exclusive.Iron case (plated iron case) can only be dry type; Gas-filled shockproof requires a stainless steel case.
Restrictions come from notes in the parameter table:
'Select dry type, iron case cannot select shockproof oil; After selecting shockproof oil, dry type or iron case cannot be selected'.
General engineering practice: Static pressure is measured in 1/3 ~ 3/4, dynamic or impulse pressure is reduced by one level.
After filling in 'Actual Working Pressure', this page will provide real-time scale utilization ratio and recommendations; Less than 30% indicates the scale is too large, and the reading accuracy is wasted; More than 75% poses a risk of overpressure.
When selecting bar, keep the value in the table; When selecting MPa, take 1/10 of the original value; When selecting psi, take 14.5 times the original value and round it, keeping at most three significant digits, and append zeros at the end.
Example: 15 bar → 1.5 MPa → 218 psi (15 × 14.5 = 217.5, rounded to three significant digits is 218).
When 'Custom Scale / Nameplate' or 'Custom LOGO' is selected as 'Yes', the additional requirements must be filled with at least 10 characters, otherwise the selection form cannot be duplicated.