Covers Y25 to Y160, a total of 10 case diameters. Select installation direction, case and connector material, accuracy, scale and thread. The system automatically assembles the model code according to the naming rules and outputs the pressure unit conversion result.
Convert according to international unit standards and common engineering definitions (1 psi = 6894.757 Pa, 1 kgf/cm² = 98066.5 Pa, 1 mmHg = 133.3224 Pa, 1 inH₂O = 249.0889 Pa).
Gauge pressureTaking atmospheric pressure as zero, all pressure gauge readings are gauge pressure;Absolute pressureTaking absolute vacuum as zero, absolute pressure ≈ gauge pressure + 101.325 kPa.
Dual scale: Inner circle bar, outer circle psi is a common practice. The "Scale" on this page also outputs MPa / psi conversions simultaneously, which can be directly referenced for reports and drawings.
kgf/cm²differs from bar by about 2%, which are two different units, not different ways of writing the same scale.
Values are all calculated from the source value, without human rounding; engineering quotes and line markings usually take 3-4 significant digits.
| Unit | Pa | kPa | MPa | bar | psi | kgf/cm² |
|---|
Bold "1" indicates the unit of this row. Column units are calculated based on the density of pure water at 4°C, and mercury columns are calculated based on the density of mercury at 0°C, consistent with industry common practices for instrument rows.
| Scale (bar) | MPa | psi | kgf/cm² | kPa | Applicable specifications |
|---|
"Applicable specifications" automatically matches the specification scale sequence in the table; the scale system of Y25 and Y30 is significantly smaller than medium and large specifications, and small specifications do not produce high-pressure scales. This table is for accurate conversion values, and dial markings follow the integer rules in Section 04.
Letters are assembled in order, numbers are case diameters, separated by "-".
Dry type and oil-filled shockproof are mutually exclusive.When selecting dry type, oil or silicone oil cannot be selected; after selecting shockproof oil, dry type cannot be selected.
Iron case and oil-filled shockproof are mutually exclusive.Iron case (plated iron case) can only be dry type; oil-filled shockproof requires a stainless steel case.
Restrictions come from parameter table annotations:
"Select dry type, iron case cannot select shockproof oil; after selecting shockproof oil, dry type or iron case cannot be selected."
General engineering method: Static pressure is "1/3 to 3/4" of the scale, and dynamic or impulse pressure is reduced by one level.After filling in "Actual working pressure", this page will give real-time scale utilization ratio and recommendations. Less than 30% indicates the scale is too large, and reading accuracy is wasted; more than 75% poses an overpressure risk.Recommended range 30% – 75%
Dial value rounding
When "Custom scale / nameplate" or "Custom LOGO" is selected as "Yes", additional requirements must be filled in with at least 10 characters, otherwise the model selection form cannot be copied.
Anhui Xingyi Instrument Co., Ltd.
Data source: