Pressure Gauge Selection System
Pressure Gauge Configurator

Select by parameter,
Real-time generation of model codes and specifications

Covers Y25 to Y160, a total of 10 case diameters. Select installation direction, case and connector material, accuracy, scale and thread. The system automatically assembles the model code according to the naming rules and outputs the pressure unit conversion result.

10 specifications 15 parameter dimensions 3 selectable units 11 pressure unit conversions
01

Parameter Selection

Options follow the specification, and inconsistent parameters will be grayed out and the reason marked.
ACase Diameter / SpecificationDetermine the applicable parameter range
BConnection DirectionRadial / Axial / With edge
CType and ShockproofDry type and oil-filled shockproof
Shockproof oil
DCase and Connector MaterialCopper / Iron / Stainless steel
Case material
Connector material
EAccuracy LevelThe smaller the value, the higher the accuracy
FScale and UnitThe scale in the table is marked in bar
Dial unit
Actual working pressure (fill in according to dial unit)
Not filled
GConnector ThreadChanges with specification
HCustom RequirementsFull specification support
Custom scale / nameplate
Custom LOGO
Additional requirements (self-input)0 / 10
Configured model
—
—
bar —
    02

    Pressure Unit Conversion

    Pressure conversion, 1 bar = 100 kPa = 14.5038 psi
    Input value
    Source unit
    Common presets

    Convert according to international unit standards and common engineering definitions (1 psi = 6894.757 Pa, 1 kgf/cm² = 98066.5 Pa, 1 mmHg = 133.3224 Pa, 1 inH₂O = 249.0889 Pa).

    Three easily confused diameters

    Gauge pressureTaking atmospheric pressure as zero, all pressure gauge readings are gauge pressure;Absolute pressureTaking absolute vacuum as zero, absolute pressure ≈ gauge pressure + 101.325 kPa.

    Dual scale: Inner circle bar, outer circle psi is a common practice. The "Scale" on this page also outputs MPa / psi conversions simultaneously, which can be directly referenced for reports and drawings.

    kgf/cm²differs from bar by about 2%, which are two different units, not different ways of writing the same scale.

    Values are all calculated from the source value, without human rounding; engineering quotes and line markings usually take 3-4 significant digits.

    Unit Conversion Table1 unit = the following value
    Unit Pa kPa MPa bar psi kgf/cm²

    Bold "1" indicates the unit of this row. Column units are calculated based on the density of pure water at 4°C, and mercury columns are calculated based on the density of mercury at 0°C, consistent with industry common practices for instrument rows.

    03

    Factory Common Scale Cross-Unit Conversion

    Automatically converted from the scale sequence in the model parameter table
    Scale (bar) MPa psi kgf/cm² kPa Applicable specifications

    "Applicable specifications" automatically matches the specification scale sequence in the table; the scale system of Y25 and Y30 is significantly smaller than medium and large specifications, and small specifications do not produce high-pressure scales. This table is for accurate conversion values, and dial markings follow the integer rules in Section 04.

    04

    Model Naming and Selection Rules

    Automatically executed based on parameter table annotations

    Naming rules

    Letters are assembled in order, numbers are case diameters, separated by "-".

    YPressure Gauge (fixed first position)
    NShockproof (oil-filled shockproof)
    BStainless steel (case)
    FAll steel (stainless steel connector)
    ZAxial direction
    TWith edge
    Example:YNBFZT-100→ Case diameter 100 mm, axial direction with edge, stainless steel case, all steel, oil-filled shockproof pressure gauge

    Mutual restrictions

    Dry type and oil-filled shockproof are mutually exclusive.When selecting dry type, oil or silicone oil cannot be selected; after selecting shockproof oil, dry type cannot be selected.

    Iron case and oil-filled shockproof are mutually exclusive.Iron case (plated iron case) can only be dry type; oil-filled shockproof requires a stainless steel case.

    Restrictions come from parameter table annotations:
    "Select dry type, iron case cannot select shockproof oil; after selecting shockproof oil, dry type or iron case cannot be selected."

    Scale verification

    General engineering method: Static pressure is "1/3 to 3/4" of the scale, and dynamic or impulse pressure is reduced by one level.After filling in "Actual working pressure", this page will give real-time scale utilization ratio and recommendations. Less than 30% indicates the scale is too large, and reading accuracy is wasted; more than 75% poses an overpressure risk.Recommended range 30% – 75%

    Dial value rounding

    When selecting bar, keep the value in the table; when selecting MPa, take 1/10 of the original value; when selecting psi, take 14.5 times the original value and round to an integer, with a maximum of three significant digits, followed by zeros.

    Example: 15 bar → 1.5 MPa → 218 psi (15 × 14.5 = 217.5, rounded to 218 with three significant digits).

    When "Custom scale / nameplate" or "Custom LOGO" is selected as "Yes", additional requirements must be filled in with at least 10 characters, otherwise the model selection form cannot be copied.

    Anhui Xingyi Instrument Co., Ltd.

    Data source:

    (Sheet1, 10 model codes × 15 parameter columns, including 3 annotation rows).Diameter description: Duplicate items in the original table "Scale (bar)" column (e.g., 50 appearing twice) have been removed; the scale unit cells for Y25 were originally numerical values 50100150200300400. This page restores them to 50 / 100 / 150 / 200 / 300 / 400. Please verify with the actual product directory.This page is a model selection auxiliary tool. The final specifications, material part numbers, and prices should be confirmed with the official quotation and drawings; the page is an offline version of a single file, and the data has been embedded in the code and cannot be accessed online.