Covers Y25 to Y160, a total of 10 case diameters. Select installation direction, case and connector material, accuracy, scale and thread pitch, system automatically assembles model code according to naming rules, and outputs pressure unit conversion results synchronously.
Convert according to international unit standards and common engineering definitions (1 psi = 6894.757 Pa, 1 kgf/cm² = 98066.5 Pa, 1 mmHg = 133.3224 Pa, 1 inH₂O = 249.0889 Pa).
Gauge PressureTaking atmospheric pressure as zero, all pressure gauge readings are gauge pressure;Absolute PressureTaking absolute vacuum as zero, absolute pressure ≈ gauge pressure + 101.325 kPa.
Dual Scale: Inner circle bar, outer circle psi is a common practice, this page 'Scale' also provides MPa / psi conversion, which can be directly compared with the report and drawings.
kgf/cm²differs from bar by about 2%, which are two different units, not different ways of writing the same scale.
Values are all calculated from source values, no human rounding is done; engineering quotes and scale markings usually take 3-4 significant digits.
| Unit | Pa | kPa | MPa | bar | psi | kgf/cm² |
|---|
The bold '1' indicates that the unit in this row is itself. Water column units are calculated based on 4 °C pure water density, mercury columns are calculated based on 0 °C mercury density, consistent with industry common practices for instrument rows.
| Scale (bar) | MPa | psi | kgf/cm² | kPa | Applicable Specifications |
|---|
'Applicable Specifications' automatically matches each specification scale in the table; Y25 and Y30 have significantly smaller scale systems than medium and large specifications, and small specifications do not produce high-pressure scales. This table is for accurate conversion values, and the dial scale marking follows the integer rule of section 04.
Letters are assembled in order, numbers are case diameters, separated by '-' in the middle.
Dry type and oil-filled shockproof are mutually exclusive.When selecting dry type, oil-filled or silicone oil cannot be selected; after selecting shockproof oil, dry type cannot be selected back.
Iron case and oil-filled shockproof are mutually exclusive.Iron case (coated iron case) can only be dry type; oil-filled shockproof requires a stainless steel case.
Exclusivity comes from parameter table notes:
'Select dry type, iron case cannot select shockproof oil; after selecting shockproof oil, dry type or iron case cannot be selected'.
General engineering practice: static pressure scale is 1/3 ~ 3/4, pulse or impact pressure is reduced by one level.
After filling in 'Actual Working Pressure', this page will display the scale utilization rate and recommendations in real time. Less than 30% indicates that the scale is too large, wasting reading accuracy; more than 75% poses a risk of overpressure.
When selecting bar, keep the value in the table; when selecting MPa, take 1/10 of the original value; when selecting psi, take 14.5 times the original value and round to the nearest integer, keeping at most three significant digits, and append zeros at the end.
Example: 15 bar → 1.5 MPa → 218 psi (15 × 14.5 = 217.5, rounded to 218 with three significant digits).
When 'Custom Scale / Nameplate' or 'Custom LOGO' is selected as 'Yes', the additional requirements must be filled in with at least 10 characters, otherwise the model cannot be copied.